Kaydee's post in APU Fire warning light comes ON when air condition is operating was marked as the answer
Thank u for your invaluable contribution. The fault was traced to a broken clamp on exhaust duct of the APU which allows the exhaust gas fall directly on the sensor loop around it. A new exhaust duct was installed, system tested and found OK.
Thanks, I will check for that and revert. Grateful
-
Kaydee's post in APU generator OUT light ON,while there is frequency, volatage and Load was marked as the answer
We found a broken cable at one of the terminals of the GCP, wire was spliced and connected back. System tested and found okay. Grateful all for your kind response
-
Kaydee's post in No frequency on phase C of engine generator was marked as the answer
I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok
-
Kaydee's post in No frequency on phase C of engine generator was marked as the answer
I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok
-
Kaydee's post in No frequency on phase C of engine generator was marked as the answer
I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok