  1. Kaydee's post in APU Fire warning light comes ON when air condition is operating was marked as the answer   
    Thank u for your invaluable contribution. The fault was traced to a broken clamp on exhaust duct of the APU which allows the exhaust gas fall directly on the sensor loop around it. A new exhaust duct was installed, system tested and found OK.
    Thanks, I will check for that and revert. Grateful
  2. Kaydee's post in APU generator OUT light ON,while there is frequency, volatage and Load was marked as the answer   
    We found a broken cable at one of the terminals of the GCP, wire was spliced and connected back. System tested and found okay. Grateful all for your kind response
  3. Kaydee's post in No frequency on phase C of engine generator was marked as the answer   
    I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok
  4. Kaydee's post in No frequency on phase C of engine generator was marked as the answer   
    I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok
  5. Kaydee's post in No frequency on phase C of engine generator was marked as the answer   
    I found that the output of the generator from the generator electrical box was not properly grounded to the engine. Cable ground repaired, system tested and found ok
×
×