  1. TIT is directly proportional to fuel flow and torque and should maintain relative values at all power settings. Discrepancies will be noted by comparing indications with the other engines. Also note throttle knob distances. If I'm not mistaken it should be no more then 1 knobs distance. The 18 thermocouples generate a millivoltage that is ampified by the respective receiving unit. A defective thermocouple will lower the indicating system by 3.5-22 degrees centigrade. Failures can effect both systems or one or the other depending on the severity of the damage. Hope all this rambling helps
×
×