Jump to content
Aero Precision provides OEM part support for military aircraft operators across more than 20 aircraft

munirabbasi

Members
  • Content Count

    340
  • Joined

  • Last visited

  • Days Won

    4

munirabbasi last won the day on December 25 2020

munirabbasi had the most liked content!

Community Reputation

18 Good

1 Follower

About munirabbasi

  • Birthday 05/20/1964

Personal Information

  • About Me
    Teacher
  • core_pfield_2
    1
  • core_pfield_4
    2
  • core_pfield_8
    8
  • core_pfield_9
    9
  • core_pfield_10
    10

core_pfieldgroups_2

  • First Name
    Munir
  • Last Name
    abbasi
  • Gender
    Male
  • Location
    Pakistan

core_pfieldgroups_3

  • Occupation
    Teacher

Recent Profile Visitors

The recent visitors block is disabled and is not being shown to other users.

  1. Thanks Munir Abbasi Home of Hercules Pakistan
  2. Sir Gary your excellent engineer/technician of electrical wiring and hope you will collect the previous best memory and reply. Munir Abbasi Home of Hercules Pakistan
  3. Hello Avionic Wiring Expertise! Kindly see yellow marked column of image and explain with technical reference Best Regards Munir Abbasi Home of Hercules Pakistan
  4. Excellent spirit and pay of attention Munir Abbasi
  5. Tanks Munir Abbasi Home of Hercules Pakistan
  6. Thanks for excellent response .let me rephrase my query regarding Engine bleed output pressure at Engines throttle higher setting. normally the pressure is indicated in flight deck bleed manifold Gage approximately 70 to 80 PSIG where one engine output pressure is 125 PSIG at 155 ppm . Question arise in my mind that one engine bleed output is metered 125psig but all four engines operating at higher throttles setting is droped to 70 to 80 psig when both air -conditioning are ruing condition with flow rate of 70 ppm and 30 ppm. Best regards Munir Abbasi Home of Hercules Pakis
  7. Hello T56A -15 power plant Pneumatic Expertise T56A-15 (C-130 E model) engine can provide approximately 155 pounds of air flow per minute at 635F and 125 pounds per square inch of gauge pressure. Bleed manifold pressure gauge is mounted in F/deck (direct gauge) display approximately 70 PSIG .where remaining pressure of the engine flow? Best Regards Munir Abbasi Home of Hercules Pakistan
  8. Hello Pneumatic expertise Identify and purpose of mark image Munir Abbasi Home of hercules Pakistan
  9. There no APU Fire alarm system is connected to air-conditioning system .Problem is APU pneumatic ducting. It might be exhaust duct partial became rapture. Best Regards Munir Abbasi Home of Hercules Pakistan
  10. Hello Sim Instructor /Engineer! Any Herks Sim Instructor know that Hercules training simulator sim programming are based on PLC or not. Which manufacture PLC is equiped with sim module. How many bit are installed on this binary program i.e 64 bits or 32 bits. Best Regards Munir Abbasi Home Hercules Pakistan
  11. Main Feature of C-130 H Model is upgrading of pneumatic system and GTC & ATM are replaced by APU system Best Regrads Munir Abbasi
  12. Happy Christmas wishes to members of Herks Munir Abbasi Home Hercules Pakistan
  13. Kamrul Ahsan Sahib. Type of GEN brushless or brush type? All ENG GEN? No load condition of GEN Voltage may exceed to 125 V until the voltage is regulated by VR , normally it does not happened.Your defect belong to malfunctioning of VR or Excitation generator poles.check the voltage "A "point (PMG) VR terminal block 1 it should be 108 volts AC (GE GEN) if Bendex type 30 V DC . If westinghouse GEN (Brush type) It has No PMG. than "F" point to A to-A of VR (TB-1) 3.75 to 7.5 Vlots (GE), Bendex 30 Volt. If brush type (Westinghouse) check boost XFMRs are mounted F.S 245. Bes
×
×